Previous
Next
This product is currently not available.
The number of potential sources of interference, such as cell phones, is constantly increasing.... more
"Coax Satellite Cable Venton RG6F-KU 140dB Copper 5-Fold HQ 100m Roll of Coaxial Cable"
The number of potential sources of interference, such as cell phones, is constantly increasing. It is all the more important that cables of all types are optimally shielded. That is why we are not satisfied with today's standard 75 dB shielding. With Venton cables, there is a whopping 140 dB, which ensures that the received signal arrives at the receiver without loss, even over long distances. For digital television enjoyment without interference.
Technical Info:
- 100 meters, spool-packed 5 compartments shielded
- Inner conductor 1.0CU - blank copper
- Insulation 4.6PE foamed, red
1. Shielding: Al / PE foil glued
2. Shielding: wire mesh, Alu-Mg alloy, 16x2x0.12 (25%)
3. Shielding: Non-glued AI / PE film
4. Shielding: wire mesh, Al-Mg alloy 16x4x0.12 (45%)
5. Shielding: Non-glued Al / PE foil
- Outer jacket 7.2mm PVC (ROHS), white
- Impedance (10MHz) 75 ohms
Nominal attenuation @ 20dB/100m:
- Max. Tolerance + 5% of the nominal damping
- 5 MHz 1.4 dB
- 50 MHz 4.7 dB
- 100 MHz 6.9 dB
- 200 MHz 9.1 dB
- 400 MHz 12.8 dB
- 800 MHz 18.2 dB
- 1600 MHz 26.3 dB
- 3000 MHz 35.9 dB
Reflection Loss:
- VHF, dB> = 20
- UHF, dB> = 20
- Impedance, 75 ohms
- Shielding dimension max. 140 dB
- Shielding attenuation corresponds to Class A according to DIN EN 50117-2-1. Coupling resistance not patent.
- Minimum shielding attenuation 94 dB
- Maximum shielding attenuation 155 dB
Abbreviations:
- KU - copper
- CCS - StaKupfer soft
- PEG - PE physically foamed
- PVC - Polyvinyl chloride
- APA - Al/Polypropylene/Al
Item no.: MONKOA-056
Technical Info:
- 100 meters, spool-packed 5 compartments shielded
- Inner conductor 1.0CU - blank copper
- Insulation 4.6PE foamed, red
1. Shielding: Al / PE foil glued
2. Shielding: wire mesh, Alu-Mg alloy, 16x2x0.12 (25%)
3. Shielding: Non-glued AI / PE film
4. Shielding: wire mesh, Al-Mg alloy 16x4x0.12 (45%)
5. Shielding: Non-glued Al / PE foil
- Outer jacket 7.2mm PVC (ROHS), white
- Impedance (10MHz) 75 ohms
Nominal attenuation @ 20dB/100m:
- Max. Tolerance + 5% of the nominal damping
- 5 MHz 1.4 dB
- 50 MHz 4.7 dB
- 100 MHz 6.9 dB
- 200 MHz 9.1 dB
- 400 MHz 12.8 dB
- 800 MHz 18.2 dB
- 1600 MHz 26.3 dB
- 3000 MHz 35.9 dB
Reflection Loss:
- VHF, dB> = 20
- UHF, dB> = 20
- Impedance, 75 ohms
- Shielding dimension max. 140 dB
- Shielding attenuation corresponds to Class A according to DIN EN 50117-2-1. Coupling resistance not patent.
- Minimum shielding attenuation 94 dB
- Maximum shielding attenuation 155 dB
Abbreviations:
- KU - copper
- CCS - StaKupfer soft
- PEG - PE physically foamed
- PVC - Polyvinyl chloride
- APA - Al/Polypropylene/Al