The number of potential sources of interference, such as cell phones, is constantly increasing. It is all the more important that cables of all types are optimally shielded. That is why we are not satisfied with today's standard 75 dB shielding. With the Venton cables, it is a whopping 120 dB, which ensures that the received signal arrives at the receiver without loss, even over long distances. For digital television enjoyment without interference.
Technical Info:
- 300 meters, reel-packed, 4 compartment shielded Staku
- Insulation / inner sheath 4.6 mm PE foamed red
1. Shielding: Al / PE foil glued
2. Shielding: wire mesh, Alu-Mg alloy, 16x2x0.12 (25%)
3. Shielding: Non-glued AI / PE film
4. Shielding: wire mesh, Al-Mg alloy 16x4x0.12 (45%)
- Outer jacket: 7mm PVC (ROHS) white
- Impedance: (10MHz) 75
Nominal attenuation @ 20dB / 100m:
- Max. Tolerance + 5% of the nominal damping
- 5 MHz 2.6 dB
- 50 MHz 4.6 dB
- 100 MHz 7.1 dB
- 200 MHz 9.9 dB
- 400 MHz 13.9 dB
- 800 MHz 19.3 dB
- 1600 MHz 27.5 dB
- 3000 MHz 36.8 dB
Reflection loss:
- VHF, dB = 20
- UHF, dB = 20
- Impedance, shielding dimension max. 120 dB
- Minimum shielding attenuation 83 dB
- Maximum shielding attenuation 128 dB
- Meter marking
Abbreviations:
- CCS - soft copper steel
- PEG - PE physically foamed
- PVC - polyvinyl chloride
- APA - Al/Polypropylene/Al
Technical Info:
- 300 meters, reel-packed, 4 compartment shielded Staku
- Insulation / inner sheath 4.6 mm PE foamed red
1. Shielding: Al / PE foil glued
2. Shielding: wire mesh, Alu-Mg alloy, 16x2x0.12 (25%)
3. Shielding: Non-glued AI / PE film
4. Shielding: wire mesh, Al-Mg alloy 16x4x0.12 (45%)
- Outer jacket: 7mm PVC (ROHS) white
- Impedance: (10MHz) 75
Nominal attenuation @ 20dB / 100m:
- Max. Tolerance + 5% of the nominal damping
- 5 MHz 2.6 dB
- 50 MHz 4.6 dB
- 100 MHz 7.1 dB
- 200 MHz 9.9 dB
- 400 MHz 13.9 dB
- 800 MHz 19.3 dB
- 1600 MHz 27.5 dB
- 3000 MHz 36.8 dB
Reflection loss:
- VHF, dB = 20
- UHF, dB = 20
- Impedance, shielding dimension max. 120 dB
- Minimum shielding attenuation 83 dB
- Maximum shielding attenuation 128 dB
- Meter marking
Abbreviations:
- CCS - soft copper steel
- PEG - PE physically foamed
- PVC - polyvinyl chloride
- APA - Al/Polypropylene/Al
EAN: 0820103253192
Product safety
| Product Number | : MONKOA-070 |
|---|---|
| WEEE Number | : |
| EAN Code | : 0820103253192 |
Responsible Person for the EU
| Name | : Multikom Delta-Sat GmbH Co. KG |
|---|---|
| Street | : Heinitzstrasse 53 |
| Location | : 58097 Hagen |
| Country | : DE |
| Phone | : +49233186086 |
| : [email protected] | |
| Website | : https://www.multi-kom.de |
Questions & Answers
You need to be logged in to ask a question